En
                                                   
                                                   
                                                   
No
Seg
St
Max. Occ.
                                               
 
SG10
O
9999
CPS-SG11
 
SG11
O
1
PAC-MEA-SG12-SG13
25
O
1
 
To specify physical measurements, including dimension tolerances, weights and counts.
Business Term
DE
EDIFACT
Format
St
*
Description
 
Measurement purpose code qualifier
an..3
M
*
  
Physical dimensions (product ordered)
 
C502
MEASUREMENT DETAILS
 
A
   
 
Measured attribute code
an..3
A
*
  
Gross volume
 
C174
VALUE/RANGE
 
R
   
 
Measurement unit code
an..3
M
 
  
litre
  
cubic metre
6314
Measurement value
an..18
R
   
Segmentstatus: Optional

This segment is used to provide measurements or dimensions relevant to the packaging unit described in the PAC segment.
           
Example:
MEA+PD+AAW+LTR:1'
   
The gross volume is 1 cubic metre.
                                                   
                                                   
Max. Occ. = Maximum Occurrence, St = Status, * = Restricted Codes
Status: M=Mandatory, R=Required, O=Optional, D=Dependent, A=Advised, N=Not used