En
                                                   
                                                   
                                                   
No
Seg
St
Max. Occ.
                                               
4
O
1
 
To head, identify and specify an object.

Notes:
1. The value in 0800 shall be unique within the interchange (except for a duplicate transfer).
2. One mandatory occurrence of S020 shall identify the Object Identification Number.
3. One occurrence of S021 is mandatory and shall be used for file format identification.
4. Data elements S302, S301, S300 and 0035 are for interactive EDI use only:
- The value(s) in S302 shall be identical to the value(s) in S302 in the preceding UIB.
- 0035, when used, test applies to the message or package only.
Business Term
DE
EDIFACT
Format
St
*
Description
 
0800
Package reference number
an..35
M
 
Unique package reference number assigned by the sender
 
S020
REFERENCE IDENTIFICATION
 
M
   
 
Reference qualifier
an..3
M
 
1
  
Object identification number
 
0802
Reference identification number
an..35
M
 
Reference number to identify a group which relates to the object.
 
S021
OBJECT TYPE IDENTIFICATION
 
M
   
 
Object type qualifier
an..3
M
 
48
  
Filter type
 
Object type attribute identification
an..256
C
 
EDA
  
UN/EDIFACT EDA filter (GS1 Permanent Code)
EDC
  
UN/EDIFACT EDC filter (GS1 Permanent Code)
HEX
  
Hexadecimal filter (GS1 Permanent Code)
 
S022
STATUS OF THE OBJECT
 
M
   
 
0810
Length of object in octets of bits
n..18
M
 
62
  
 
0814
Number of segments before object
n..3
C
 
PCKS7
  
 
S302
DIALOGUE REFERENCE
 
C
   
 
0300
Initiator control reference
an..35
M
 
Length of the object attached in bytes
The digital certificate will be attached using PKCS#7 format because it allows including more than one digital certificate (User Certificate and the Certification Chain).  This file will be filtered using EDC or Hexadecimal filter.
Once the file is filtered, the total number of bytes of the object to be attached will be obtained and detailed in DE0810.
Function:
To head, identify and specify an object.

Notes:
1. The value in 0800 shall be unique within the interchange (except for a duplicate transfer).
2. One mandatory occurrence of S020 shall identify the Object Identification Number.
3. One occurrence of S021 is mandatory and shall be used for file format identification.
4. Data elements S302, S301, S300 and 0035 are for interactive EDI use only:
- The value(s) in S302 shall be identical to the value(s) in S302 in the preceding UIB.
- 0035, when used, test applies to the message or package only.
           
Example:
UNO+OB000001+1:CER123+48:EDC+62:PCKS7+9'
Example:
UNO+OB000001+1:CER123+46:EDC*62:PKCS7+1238'
                                                   
                                                   
Max. Occ. = Maximum Occurrence, St = Status, * = Restricted Codes
Status: M=Mandatory, R=Required, O=Optional, C=Conditional, D=Dependent, A=Advised, N=Not used