No
Seg
St
Max. Occ.
                                               
5
M
5
 
To specify date, and/or time, or period.
Business Term
DE
EDIFACT
Format
St
*
Description
 
C507
DATE/TIME/PERIOD
 
M
   
 
2005
Date or time or period function code qualifier
an..3
M
*
  
Document/message date/time
 
2380
Date or time or period value
an..35
R
   
 
2379
Date or time or period format code
an..3
R
 
  
CCYYMMDD
This segment is used to specify any dates related to the complete message.
DE 2005: Identification of the 'Document/message date/time' (code value 137) is mandatory in an EANCOM message.
Example:
The Drawing Administration Message was created on the 30th of August 2002.
           
Example:
DTM+137:X:102'
Example:
DTM+137:20020830:102'
                                                   
                                                   
Max. Occ. = Maximum Occurrence, St = Status, * = Restricted Codes
Status: M=Mandatory, R=Required, O=Optional, C=Conditional, D=Dependent, A=Advised, N=Not used